I Thought I would follow up on this post so that somebody else my learn something ... After messing around with the bike , I found two problems that I got lazy with after checking so many connectors and wiring and so on ... First off , I had a bad plug cap that the screw that the wire feeds into...
Yeh thanks , it must be , the bike runs great now after finding a couple gremlins in the electrical system so the readings I got must be normal as the pulse generator was not the problem ....
Pulse generator on a 91 cb750 ... spec per manual is 297 - 383 ohms ... I measure 360 ohms cold and 410 ohms hot ... Normal or should I replace it ... Thanks for any help you can provide
Hello , thanks for the reply , carbs are synced the best I can right at the moment , I just removed the valve cover to check the timing and its spot on , the motor is very clean inside ... Side note , I realize its not a cdi persay but a ICM module , completely different animal
I ll make this quick , bought a project 91 CB750 (15000 miles All stock) , bought it with the carbs in pieces in a tray , seller bought it like this from somebody else ... Anyway , like a blind squirrel with a service manual , I got it back running but its not good . Its running lean and...